Henoistasis reagents

Thrombophilia

Sysmex provides high-quality specialty reagents for investigating hypercoagulability in your critical patients.

Test Product Description Reagent State Material Number Kit Size Tests/Kit
Antithrombin INNOVANCE® Antithrombin Chromogenic assay for the quantitative determination of functional antithrombin. The human factor Xa-based reagent has minimal interference with heparin cofactor II and thrombin inhibitors such as hirudin. Ready-to-use liquid reagents. Liquid MST 10873856, 10873911, 10873857 Small Kit, Medium Kit, Large Kit 150, 300, 450
Protein C Protein C Reagent Coagulometric reagent used for the quantitative determination of protein C activity. The reagent is suitable for the detection of hereditary or acquired protein C deficiencies. 10873871 Kit 50
Protein C Berichrom® Protein C Chromogenic activity assay. This is used for the detection of hereditary or acquired protein C deficiency types. The assay is also used for the monitoring of substitution therapy with protein C concentrates in congenital protein C deficiency. This assay is less susceptible to interfering substances than a clotting assay. MST 10873892, 10873893 Large Kit, Small Kit 180, 120
Protein S INNOVANCE® Free PS Ag This is for the quantitative detection of free protein S. It is a latex-particle enhanced immunoassay utilizing two monoclonal antibodies that have high specificity for free protein S and do not bind to protein S/C4b-binding protein complexes. The high specificity also shows no major interferences, including interferences commonly incurred from rheumatoid factors and heterophilic antibodies. Ready-to-use liquid reagent. Liquid MST 10873858 Kit 160
Activated Protein C Resistance / Factor V Leiden Factor V Leiden This is a dilute Russell’s viper venom test with a sensitivity and specificity of > 99%, which screens for APC resistance due to the presence of factor V Leiden mutation in patient samples. This reagent is insensitive to heparin and is not influenced by high levels of factor VIII. 10873848 Kit 150
Lupus Anticoagulant LA 1 Screening Reagent This reagent contains dilute Russell’s viper venom and low phospholipids for use in the simplified DRVVT as a screening test for the presence of lupus anticoagulants. MST 10446063 10×2 mL 180
Lupus Anticoagulant LA 2 Confirmation Reagent This reagent is a simplified dilute Russell’s viper venom time rich in phospholipids, aimed for the confirmation of the presence of lupus anticoagulants MST 10446064 10×1 mL

MST = Minimal standing time (0-5 min) after reconstitution
For reagent package inserts and other applicable documentation, please visit the Sysmex Customer Resource Center.