Compare Hematology Analyzers

XQ-320™ Automated Hematology Analyzer
Simple, fast, accurate automation
With XQ-320, your CBC testing is always reliable and accurate. Offering 17 parameters, including a dedicated neutrophil count, the XQ-320 is the right solution for physician office labs, stat labs or wherever high-quality diagnostic testing results with a short turnaround time are required.
Ideal for:
- Physician Office Labs
- Ambulatory Care Centers
- Clinics
- Backup Analyzer
Summary

Dimension / Weights
14” x 17.5” x 17” / 48.5 lbs

Maximum Throughput
60 samples per hour (pre-dilution mode)
70 samples per hour (whole blood mode)
70 samples per hour (whole blood mode)

Sample Volume
Whole Blood Mode: 16μL
Pre-dilute Mode: 65μL (20μL blood required)
Pre-dilute Mode: 65μL (20μL blood required)

pocH-100i™ Hematology Analyzers
Innovative, easy, reliable technology.
Designed for laboratories testing up to 30 samples per day, in a tiny footprint
Ideal for:
- Physician Office Labs
- Ambulatory Care Centers
- Clinics
- Backup Analyzer
Summary

Dimension / Weights
7.3" (W) X 13.8" (D) X 18.1" (H); 30.8 LBS

Maximum Throughput
25 samples/hour

Sample Volume
Whole Blood Mode: 15μL EDTA

XN-450™ Automated Hematology Analyzer
Intelligent, compact analyzer offers big benefits for your small lab
The XN-450 is a closed-mode sampler integrated IPU with LCD color touchscreen and intuitive XN software. With the clinical and operational values found on its sister XN-Series™, the XN-450 analyzers brings small labs powerful diagnostics and reliable analysis to help optimize your lab's performance.
Ideal for:
- Physician Office Labs
- Ambulatory Care Centers
- Clinics
- Backup Analyzer
Summary

Dimension / Weights
7.7” X 17.3” X 18.1” / approx. 77.2 lbs.

Maximum Throughput
Up to 60 samples/hour in whole blood (WB) mode

Sample Volume
Whole Blood Mode: 25 μL
Pre-dilute Mode: 70 μL
Body Fluid Mode: 70 μL
Pre-dilute Mode: 70 μL
Body Fluid Mode: 70 μL

XN-550™ Automated Hematology Analyzer
Intelligent, affordable automation for lower volume labs
The XN-550 provides expanded clinical and operational values to your small hospital, clinic or physician's office laboratory. With automation and a six-part differential on every sample, this compact analyzer provides the standardization and diagnostics your lab needs.
Ideal for:
- Physician Office Labs
- Ambulatory Care Centers
- Clinics
- Small Hospitals
- Backup Analyzer
Summary

Dimension / Weights
17.72"" x 25.98"" x 17.72"" / 116.84 lbs
XN-530 Monitor: 10.5” X 8.25” X 9.5” (2.25” thick)
XN-530 Monitor: 10.5” X 8.25” X 9.5” (2.25” thick)

Maximum Throughput
Up to 60 samples/hour in whole blood (WB) mode

Sample Volume
"Open Mode 25 mm
Closed Mode 25 mm
Pre-dilute mode: 70µL
Body Fluid Mode: 70µL"
Closed Mode 25 mm
Pre-dilute mode: 70µL
Body Fluid Mode: 70µL"
Additional Specifications
Technology
Cyanide-Free SLS Method
Hemoglobin
Cyanide-Free SLS Method
Hemoglobin
Cyanide-Free SLS Method
Hemoglobin
Cyanide-Free SLS Method
Hemoglobin
DC Impedance method with Hydrodynamic Focusing
WBC
RBC
PLT
DC Impedance method with Hydrodynamic Focusing
WBC
RBC
PLT
DC Impedance method with Hydrodynamic Focusing
RBC
PLT
DC Impedance method with Hydrodynamic Focusing
RBC
PLT
Fluroscent Flow Cytometry
Not Applicable
Fluroscent Flow Cytometry
Not Aplicable
Fluroscent Flow Cytometry
WBC
6-part differential (IG #, %)
Fluroscent Flow Cytometry
WBC
6-part differential (IG #, %)
Linearity
WBC: 1.00 – 99.90 X 10^3/µL
RBC: 0.30 – 7.00 X 10^6/µL
HGB: 0.1 – 25.0 g/dL
HCT: 10.0 – 60.0%
PLT: 10 – 999 X 103/µL
RBC: 0.30 – 7.00 X 10^6/µL
HGB: 0.1 – 25.0 g/dL
HCT: 10.0 – 60.0%
PLT: 10 – 999 X 103/µL
Linearity
WBC 1.0 – 99.0 X 103/μL
RBC 0.3 – 7.0 X 106/μL
HGB 0.1 – 25.0 g/dL
HCT 10 – 60%
PLT 10 – 999.9 X 103/μL
RBC 0.3 – 7.0 X 106/μL
HGB 0.1 – 25.0 g/dL
HCT 10 – 60%
PLT 10 – 999.9 X 103/μL
Linearity
WBC: 0.00 – 440.00 X 10^3/μL
RBC: 0.00 – 8.60 X 10^6/μL
PLT: 0 – 5,000 X 10^3/μL
RBC: 0.00 – 8.60 X 10^6/μL
PLT: 0 – 5,000 X 10^3/μL
Linearity
WBC: 0.00 - 440.0 X 10^3/mL
RBC: 0.00 - 8.6 X 10^6/mL
PLT: 0 - 5,000 X 10^3/mL
RBC: 0.00 - 8.6 X 10^6/mL
PLT: 0 - 5,000 X 10^3/mL
Optional Parameters
None
Optional Parameters
None
Optional Parameters
Optional RET License:
RET#; RET%, IRF; RET-He
Optional BF License:
TC-BF, WBC-BF, RBC-BF, MN#, MN%, PMN#, PMN%
RET#; RET%, IRF; RET-He
Optional BF License:
TC-BF, WBC-BF, RBC-BF, MN#, MN%, PMN#, PMN%
Optional Parameters
Optional RET License:
RET#; RET%, IRF; RET-He
Optional BF License:
TC-BF, WBC-BF, RBC-BF, MN#, MN%, PMN#, PMN%
RET#; RET%, IRF; RET-He
Optional BF License:
TC-BF, WBC-BF, RBC-BF, MN#, MN%, PMN#, PMN%
Parameters
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, LYM#
LYM%, MXD#, MXD%, NEUT#, NEUT%, RDW-SD, RDW-CV, MPV
Parameters
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, LYM#, LYM%, MXD#, MXD%, NEUT#, NEUT%, RDW-SD, RDW-CV, MPV
Parameters
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MPV, NEUT#, NEUT%; IG#, IG%; LYMPH#, LYMPH%; MONO#, MONO%; EO#, EO%; BASO#, BASO%; Retic Parameters with Optional License: RET#; RET%, IRF; RET-He; Body Fluid Parameters with Optional License: TC-BF, WBC-BF, RBC-BF PMN #, PMN%, MN#, MN%
Parameters
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MPV, NEUT#, NEUT%; IG#, IG%; LYMPH#, LYMPH%; MONO#, MONO%; EO#, EO%; BASO#, BASO%; Retic Parameters with Optional License: RET#; RET%, IRF; RET-He; Body Fluid Parameters with Optional License: TC-BF, WBC-BF, RBC-BF PMN #, PMN%, MN#, MN%
Principles and Technology
WBC, RBC, PLT: Direct Current method
HGB: Non-cyanide HGB analysis method
HCT: Cumulative pulse height detection method
HGB: Non-cyanide HGB analysis method
HCT: Cumulative pulse height detection method
Principles and Technology
RBC, PLT, WBC: Direct Current detection method
HGB: Non-cyanide method
HCT: Cumulative pulse height detection method
HGB: Non-cyanide method
HCT: Cumulative pulse height detection method
Principles and Technology
Fluorescent Flow Cytometry (WBC/6-part DIFF/NRBC Flagging), DC Impedance method with hydrodynamic focusing (RBC/PLT), Cyanide-free SLS method (HGB)
Principles and Technology
Fluorescent Flow Cytometry (WBC/6-part DIFF/NRBC Flagging), DC Impedance method with hydrodynamic focusing (RBC/PLT), Cyanide-free SLS method (HGB)
RBC Pulse Height Detection
HCT
RBC Pulse Height Detection
HCT
RBC Pulse Height Detection
HCT
RBC Pulse Height Detection
HCT
Other
BCQMh
Real-time peer group comparison
BCQMh
None
BCQMh
Real-time peer group comparison
BCQMh
Real-time peer group comparison
Continuous Calibration Verification
Confirmed every time controls are analyzed
Continuous Calibration Verification
None
Continuous Calibration Verification
Confirmed every time controls are analyzed
Continuous Calibration Verification
Confirmed every time controls are analyzed
Interface
Bi-directional
Interface
Uni-directional
Interface
Bi-directional
Interface
Bi-directional
Decision Rules Onboard
None
Decision Rules Onboard
None
Decision Rules Onboard
Comment, validation and output rules
Decision Rules Onboard
Automatic Rerun/Reflex rules
Printers
External printer included
Printers
Internal printer included
Printers
External printer included
Printers
External printer included
Remote Monitoring
Sysmex Network Communications System (SNCS)
Remote Monitoring
None
Remote Monitoring
Included
Remote Monitoring
Included
Training
Online training
Training
Online training
Training
Unlimited Virtual Instructor-Led Training
Training
Unlimited Virtual Instructor-Led Training
Reagents and Controls
Controls and Calibrators
EIGHTCHECK™-3WP X-TRA tri-level QC material
SCS-1000™ Calibration material
SCS-1000™ Calibration material
Controls and Calibrators
EIGHTCHECK™-3WP X-TRA tri-level
Controls and Calibrators
XN-L CHECK™
XN CHECK™
XN CHECK™ BF (required with optional BF License)
WRP CHECK™ EX
XN CHECK™
XN CHECK™ BF (required with optional BF License)
WRP CHECK™ EX
Controls and Calibrators
XN-L CHECK™
XN CHECK™
XN CHECK™ BF (required with optional BF License)
WRP CHECK™ EX
XN CHECK™
XN CHECK™ BF (required with optional BF License)
WRP CHECK™ EX
Reagents
CELLPACK™
STROMATOLYSER™-WH
CELLCLEAN™
STROMATOLYSER™-WH
CELLCLEAN™
Reagents
pocH-pack D
pocH-pack L
XW CELLCLEAN™
pocH-pack L
XW CELLCLEAN™
Reagents
CELLPACK™ DCL
CELLPACK™ DFL
SULFOLYSER™
Lysercell™ WDF
Fluorocell™ WDF
Fluorocell™ RET
CELLCLEAN™ Auto
CELLPACK™ DFL
SULFOLYSER™
Lysercell™ WDF
Fluorocell™ WDF
Fluorocell™ RET
CELLCLEAN™ Auto
Reagents
CELLPACK™ DCL
CELLPAK DFL
SULFOLYSER™
Lysercell™ WDF
Fluorocell™ WDF
Fluorocell RET
CELLCLEAN™ Auto
CELLPAK DFL
SULFOLYSER™
Lysercell™ WDF
Fluorocell™ WDF
Fluorocell RET
CELLCLEAN™ Auto