Hemophilia & Bleeding Disorders
Factor deficient plasma reagents from Sysmex are industry tested and trusted and offer the sensitivity and reliability you patients deserve.
| Test | Product | Description | Reagent State | Material Number | Kit Size | Tests/Kit |
|---|---|---|---|---|---|---|
| Factor deficient plasmas (for one-stage factor activity testing) | Coagulation Factor VIII Deficient Plasma | Human plasma-based reagent for the detection of hereditary or acquired deficiencies of factor VIII. Contains a residual factor activity of < 1% factor VIII activity. | 10873880 | 8×1 mL | 144 | |
| Factor deficient plasmas (for one-stage factor activity testing) | Coagulation Factor IX Deficient Plasma | Human plasma-based reagent for the detection of hereditary or acquired deficiencies of factor IX. Contains a residual factor activity of < 1% factor IX activity. | 10873881 | 8×1 mL | 144 | |
| Factor deficient plasmas (for one-stage factor activity testing) | Coagulation Factor XI Deficient Plasma | Human plasma-based reagent for the detection of hereditary or acquired deficiencies of factor XI. Contains a residual factor activity of < 1% factor XI activity | 10873883 | 3×1 mL | 54 | |
| Factor deficient plasmas (for one-stage factor activity testing) | Coagulation Factor XII Deficient Plasma | Human plasma-based reagent for the detection of hereditary or acquired deficiencies of factor XII. Contains a residual factor activity of < 1% factor XII activity. | 10873877 | 3×1 mL | 54 | |
| Factor deficient plasmas (for one-stage factor activity testing) | Coagulation Factor II Deficient Plasma | Human plasma-based reagent for the detection of hereditary or acquired deficiencies of factor II. Contains a residual factor activity of < 1% factor II activity. | 10873878 | 3×1 mL | 54 | |
| Factor deficient plasmas (for one-stage factor activity testing) | Coagulation Factor V Deficient Plasma | Human plasma-based reagent for the detection of hereditary or acquired deficiencies of factor V. Contains a residual factor activity of < 1% factor V activity. | 10873875 | 8×1 mL | 144 | |
| Factor deficient plasmas (for one-stage factor activity testing) | Coagulation Factor VII Deficient Plasma | Human plasma-based reagent for the detection of hereditary or acquired deficiencies of factor VII. Contains a residual factor activity of < 1% factor VII activity. | 10873879 | 3×1 mL | 54 | |
| Factor deficient plasmas (for one-stage factor activity testing) | Coagulation Factor X Deficient Plasma | Human plasma-based reagent for the detection of hereditary or acquired deficiencies of factor X. Contains a residual factor activity of < 1% factor X activity. | 10873882 | 3×1 mL | 54 | |
| Factor VIII Chromogenic Assay | Factor VIII Chromogenic Assay | Recommended for factor FVIII determination in therapeutic factor FVIII preparations and the detection of hereditary or acquired factor VIII deficiencies. | 10873840 | Kit | 90 | |
| Factor XIII Chromogenic Assay | Berichrom® F XIII | Chromogenic, quantitative assay for the detection of hereditary or acquired factor XIII deficiencies. This is also used for the monitoring of patients undergoing factor XIII substitution therapy. | 10873897 | Kit | 135 | |
| Von Willebrand disease | INNOVANCE® VWF Ac | This kit is used for direct determination of VWF activity. It employs an advanced technology allowing the assay to mimic the binding of VWF to glycoprotein Ib (GPIb), the major VWF receptor protein on platelets. Latex particles are coated with an antibody against GPIb, to which recombinant GPIb is added. The addition of patient plasma induces a VWF-dependent agglutination, which is detected turbidimetrically. Because the recombinant receptor protein includes two gain-of-function mutations, the assay does not require ristocetin. | Liquid MST | 10873897 | Kit | 90 |
| Von Willebrand disease | BC von Willebrand Reagent | This is for the determination of the ristocetin cofactor activity of von Willebrand factor. The reagent is sensitive to types 1, 2, and 3 of von Willebrand disease (except VWD 2N) and is the recommended screening method for von Willebrand disease. | 10873912 | 5×4 mL | 125 | |
| Von Willebrand disease | vWF Ag | Quantitative, automated immunoassay used to determine the differentiation of quantitative versus qualitative von Willebrand factor deficiencies. It is sensitive to type 1 and 3 VWF deficiencies and offers a wide measuring range of 2–600% of the norm. | Liquid | 10445967 | Kit | 240 |
MST = Minimal standing time (0-5 min) after reconstitution
For reagent package inserts and other applicable documentation, please visit the Sysmex Customer Resource Center.